Metal-on-Metal Hip Resurfacing: The Effect of Component Position and Size on the Range of Motion to Impingement

Updated 11/30/08

Link http://proceedings.jbjs.org.uk/cgi/content/abstract/88-B/SUPP_III/432

2006

D.H. Williams; U. Masood; and M.N. Norton

Royal Cornwall Hospital, Truro, Cornwall TR1 3LJ, UK.

Decreased head-neck ratio diameter and component malposition in total hip arthroplasty are factors known to result in impingement, increased rates of dislocation, wear and failure. In addition to these complications, impingement of the femoral neck on the acetabular component of a hip resurfacing may result in femoral neck fracture and loosening of the acetabular component. Little is known regarding the optimum femoral and acetabular hip resurfacing component position to avoid impingement.

In the first part of this study we analyzed the radiographic component position of 131 consecutive hip resurfacings. In the second part the effect of three component variables on the range of motion to impingement were analyzed using a dry bone model:

  1. Inclination of the acetabular cup
     

  2. Version of the acetabular cup
     

  3. Femoral head-neck diameter ratio

The mean femoral-stem shaft angle in the first part of the study was 138° (range 121° to 158°). The mean acetabular inclination angle was 45° (range 30° to 63°). This wide range in position mirrors that described in the literature. The dry bone study revealed an optimum acetabular cup inclination tending towards 50° and an anteversion of 25°. A large diameter femoral head relative to the femoral neck resulted in a greater range of motion to impingement. A fine balance however exists, to remove a minimum amount of pelvic bone to accommodate a larger acetabular component with an ‘oversized’ femoral component.

The acetabular resurfacing cup positions described allow the greatest range of physiological hip movement. New technology and improvements to existing equipment and techniques will hopefully lead to more accurate placement of hip resurfacing components minimising the risk of impingement and its complications in this high demand group of patients

Correspondence should be addressed to SWOC, c/o Mr David Bracey, Royal Cornwall Hospital, Truro, Cornwall, TR1 3LJ.

Advertisement


View My Stats

Statistics Page

Web design by Patricia Walter Copyright Surface Hippy 12/11/2005

Mission Statement - Surface Hippy is a patient to patient guide to hip resurfacing. It does not provide medical advice. It is designed to support, not to replace, the relationship between patient and clinician.
Advertising - Revenue from this site is derived from commercial advertising and individual donations.
Any advertisement is distinguished by the word "advertisement"
Privacy - Surface Hippy does not share email addresses or personal information with any group or organization.
Content - Surface Hippy is not controlled or influenced by any medical companies, doctors or hospitals.
All content is controlled by Patricia Walter  -
Joint Health Sites  LLC
This site is published by Joint Health Sites LLC, which is solely responsible for its content.
The advertisements on this site are not intended by the advertisers as an endorsement of the site's content.
The advertisers shall not be liable for any errors or omissions in the site's content,
nor liable for any damages from any person's actions based in reliance on the site's content.