Hip Resurfacing News

Larger cups and optimal positioning produced lowest ion levels and wear study by David Langton

Updated 3/10/2010

Larger cups and optimal positioning produced lowest ion levels and wear

In a review of 585 blood serum evaluations following hip resurfacing, only femoral size and cup inclination were found to have an effect on ion levels, according a study by orthopedic investigators.

The findings were presented at the 2010 Annual Meeting of the American Academy of Orthopaedic Surgeons.

David J. Langton, MRCS, and his colleagues also found that the size of the coverage angle of the acetabular component contributed significantly to its tolerance of suboptimal positioning.

"Larger joints, it must be emphasized, tolerated suboptimal cup position," he said. "This must be taken into account in all analyses."

Inverse relationships

Using routinely obtained blood serum metal ion levels from patients under the care of the two senior authors of the paper being presented - both highly experienced hip resurfacing surgeons - metal ion results were analyzed regarding their relationship to femoral and acetabular component size and orientation, UCLA activity score, age, time post surgery and postoperative femoral head/neck ratios.

Langton reported an inverse relationship between metal ion levels and femoral size. A smaller acetabular coverage arc was associated with higher metal ion levels.

Another significant inverse correlation was noted by Langton between metal ion levels and contact patch to rim (CPR) distance. CPR is a measurement that relates the position of the articular contact patch with the patient in standing position to the cup rim. According to the abstract, CPR less than 5 mm is associated with a 50% chance of ion levels greater than 30 mg/L.

Words of warning

Langton warned the audience, "To increase metal ion levels as quickly as possible, use as small a bearing diameter as possible, use a cup with the smallest coverage arc, and combine very high anteversion with high inclination."

He concluded, "Cups placed with angles between 40° and 50° inclination and 10° to 20° anteversion have the lowest ion levels and the lowest rates of volumetric wear."

  • Reference:

Langton D, Jameson S, Joyce T, et al. A review of 585 serum metal ion results post hip resurfacing: cup design and position is critical. Paper 006. Presented at the 2010 Annual Meeting of the American Academy of Orthopaedic Surgeons. March 9-13. New Orleans.

Langton has received research or institutional support from DePuy, a Johnson & Johnson Company, DJ Orthopaedics; he has also received miscellaneous non-income support (e.g., equipment or services) from DePuy, a Johnson & Johnson Company.

 

Advertisement


View My Stats

Statistics Page

Web design by Patricia Walter Copyright Surface Hippy 12/11/2005

Mission Statement - Surface Hippy is a patient to patient guide to hip resurfacing. It does not provide medical advice. It is designed to support, not to replace, the relationship between patient and clinician.
Advertising - Revenue from this site is derived from commercial advertising and individual donations.
Any advertisement is distinguished by the word "advertisement"
Privacy - Surface Hippy does not share email addresses or personal information with any group or organization.
Content - Surface Hippy is not controlled or influenced by any medical companies, doctors or hospitals.
All content is controlled by Patricia Walter  -
Joint Health Sites  LLC
This site is published by Joint Health Sites LLC, which is solely responsible for its content.
The advertisements on this site are not intended by the advertisers as an endorsement of the site's content.
The advertisers shall not be liable for any errors or omissions in the site's content,
nor liable for any damages from any person's actions based in reliance on the site's content.